Search results for " Conductive"

showing 10 items of 30 documents

Hearing loss in Fabry disease: data from the Fabry Outcome Survey

2006

Hearing loss is a common symptom in Fabry disease, but neither its natural course nor its aetiology has been defined precisely. The aim of this study was to provide a detailed epidemiological description of hearing impairment in patients in the Fabry Outcome Survey (FOS), which is the largest available database of Fabry patients. Questionnaires were completed by 566 Fabry patients, of whom 316 reported ear-related symptoms. Pure-tone audiograms from 86 patients, performed before starting enzyme replacement therapy, were analysed and compared with age- and sex-specific normal values (International Organization for Standardization, ISO 7029). When compared to an age-matched population (ISO 70…

AdultMalemedicine.medical_specialty1303 BiochemistryAdolescentHearing lossHearing Loss SensorineuralHearing Loss ConductiveClinical BiochemistryPopulationPresbycusis610 Medicine & health10045 Clinic for OtorhinolaryngologyAudiology1308 Clinical BiochemistryBiochemistrySex Factorsotorhinolaryngologic diseasesmedicineHumansChildHearing LosseducationAgededucation.field_of_studymedicine.diagnostic_testbusiness.industryIncidenceGeneral MedicineAudiogramEnzyme replacement therapyMiddle Agedmedicine.diseaseFabry diseaseSurgeryConductive hearing lossEuropeChild PreschoolHealth Care SurveysSensory Thresholdsalpha-GalactosidaseAudiometry Pure-ToneFabry DiseaseFemaleAudiometrymedicine.symptombusiness
researchProduct

Otosclerosis associated with type B-1 inner ear malformation

2010

Malformations of bony inner ear are rare anomalies occurring in approximately 20% of patients with congenital sensorineural hearing loss. Conductive hearing loss is usually associated with abnormalities of the external and middle ear. Recent reports of patients with lateral semicircular canal malformations indicate inner ear malformations to be associated with sensorineural or conductive hearing loss. Differential diagnosis of conductive hearing loss should include otosclerosis, isolated ossicular deformities, inner ear anomalies or a combination of these. In this report, a case is described with right vestibule-lateral semicircular canal dysplasia presenting at our centre with bilateral ot…

AdultOtosclerosisEar InnerHearing Loss Conductiveotorhinolaryngologic diseasesHumansCase ReportFemaleInner ear malformationLateral semicircular canal dysplasiasense organsConductive hearing lossStapedotomy
researchProduct

BIOACTIVE GLASS CERAMIC

1983

The practicability of the bioactive glass ceramic Cernvitnl® in ear surgery was tested in animals. The histological findings are presented. Over the last 3 years implants of bioactive glass ceramic were used in humans. Prostheses for the total or partial reconstruction of the ossicular chain and the reconstruction of the bony wall of the outer ear canal were fashioned. We have conducted about 300 tympanoplasties and 60 total or partial reconstructions of the bony wall of the outer ear canal. The otoscopic and functional results were satisfactory.

CeramicsTympanic Membranemedicine.medical_treatmentHearing Loss ConductiveDentistryBiocompatible Materialslaw.inventionTympanoplastyOsteogenesislawotorhinolaryngologic diseasesmedicineOuter earAnimalsHumansCeramicEar OssiclesOssicular chainbusiness.industryProstheses and ImplantsTympanoplastymedicine.anatomical_structureOtorhinolaryngologyBioactive glassvisual_artvisual_art.visual_art_mediumGlassRabbitssense organsbusinessEar CanalThe Laryngoscope
researchProduct

Congenital adrenal hypoplasia and hearing loss. A case report

1995

We report on the diagnostics, the therapeutics and the follow-up (to 3 years and 5 months) of a newborn affected by X-linked congenital adrenal hypoplasia. After the beginning of substitute hormonal therapy, the patient underwent periodical clinical examinations, with particular attention to the growth, and laboratory tests, which monitored the hormonal pattern. This experience points out the diagnostic role of low maternal levels of urinary estriol during pregnancy and the importance of a prolonged follow-up, so as to discover associated pathologies as early as possible. In our case, in fact, the study of auditory brainstem responses enabled us to recognize a mild transmission hearing loss…

CortisoneMalenot availableTime FactorsMineralocorticoidsHearing Loss ConductiveAdrenal Gland DiseasesInfant NewbornHumansFollow-Up StudiesPedigree
researchProduct

Electrically Conductive Phthalocyanine Assemblies. Structural and Non-Integer Oxidation Number Considerations

1990

Aggregation is a well-known phenomenon in phthalocyanine chemistry. Interactions can occur between adjacent phthalocyanine rings, both in organic and aqueous phases, resulting in coupling between the electronic states of two, or more, phthalocyanine units [1].

Coupling (electronics)chemistry.chemical_compoundAqueous solutionMaterials sciencechemistryPolymer chemistryPhthalocyanineMolecular planeElectrically conductivePhotochemistryElectric chargeInteger (computer science)Electronic states
researchProduct

Numerical Modelling of Room Thermal Comfort Conditions

2006

Particular heat transfer coefficients of building elements gives quantitative notion only about heat losses through this building element. Analysis of the overall heat balance and heat losses of complete building and study of particular contribution of building elements in overall balance allows one to figure out the state of the building and find the building elements of bounding construction with most significant heat losses. Project variants of the buildings (or rebuilding in case of renovation), which ensure the desirable economy of energy and proportions of investments can be find varying the proportions of the surface area of building elements (e.g., windows and doors). A lot of facto…

EngineeringComputer simulationbusiness.industryBounding overwatchPassive coolingHeat exchangerMechanical engineeringThermal comfortHeat transfer coefficientConstant (mathematics)businessmathematical modelling; numerical simulation; hydrodynamics; heat exchange; convective and conductive heat losses; ANSYS/Flotran; boundary constructions; temperature and air flow distribution; thermal comfort conditionsBlock (data storage)Environment. Technology. Resources. Proceedings of the International Scientific and Practical Conference
researchProduct

Protecting emergency workers and armed forces from volatile toxic compounds: Applicability of reversible conductive polymer-based sensors in barrier …

2019

International audience; Barrier materials have wide applicability in both professional (military, medical, industrial) and non-professional(leisure and sports) fields. This paper focuses on the preparation of real conductive polymer (CP) sensors, for thestudy of the permeation of volatile toxic compounds through barrier materials. Use of such a CP sensor can helpimprove the quality of barrier materials used in protective clothing. Several types of platforms have beenmanufactured or purchased for use as comb sensors with different electrode dimensions, and a suitable methodof applying the detection layer of conductive polymers (polyaniline and poly-pyrrole) has been developed. Prepared senso…

Environmental EngineeringMaterials science010504 meteorology & atmospheric sciencesReversible conductive polymer-based sensorSubstrate (electronics)Air Pollutants Occupational010501 environmental sciencesConductivity01 natural sciencesSurface filmchemistry.chemical_compoundQCM sensor platformOccupational ExposurePolyanilineEnvironmental ChemistryVolatile toxic compoundsWaste Management and Disposal0105 earth and related environmental sciencesConductive polymerPermeationPollutionMilitary PersonnelchemistryChemical engineeringElectrode[SDE]Environmental SciencesEmergency Service HospitalLayer (electronics)Military textile barrier materialPermeation cellEnvironmental Monitoring
researchProduct

Optimization of ZnO:Al/Ag/ZnO:Al structures for ultra-thin high-performance transparent conductive electrodes

2012

Al-doped ZnO (AZO)/Ag/AZO multilayer coatings (50-70 nm thick) were grown at room temperature on glass substrates with different silver layer thickness, from 3 to 19 nm, by using radio frequency magnetron sputtering. Thermal stability of the compositional, optical and electrical properties of the AZO/Ag/AZO structures were investigated up to 400 °C and as a function of Ag film thickness. An AZO film as thin as 20 nm is an excellent barrier to Ag diffusion. The inclusion of 9.5 nm thin silver layer within the transparent conductive oxide (TCO) material leads to a maximum enhancement of the electro-optical characteristics. The excellent measured properties of low resistance, high transmittanc…

High transmittanceDiffusionrf-Magnetron sputteringElectro-optical characteristicGlass substrateTransparent conductive oxide RF magnetron sputtering Optical properties Electrical resistivity Al-doped zinc oxide Silver MultilayersSettore ING-INF/01 - ElettronicaSUBSTRATE-TEMPERATUREAg diffusionAl-doped ZnOLow resistanceMultilayerZNOMaterials ChemistryVisible spectral rangeMULTILAYER FILMSAl-doped zinc oxideOptical propertiesMetals and AlloysAZO filmElectrical resistivityOPTICAL-PROPERTIESOXIDE-FILMSSurfaces and InterfacesZinc oxide AluminumRadio frequency magnetron sputteringSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsOptical and electrical propertieElectrodeOptoelectronicsFilm preparationLayer (electronics)Magnetron sputteringUltra-thinRF magnetron sputteringMaterials scienceSilverThermodynamic stabilityOpticsTransparent conductive oxideElectrical resistivity and conductivityThermal stabilityElectrical conductorTransparent conducting filmRoom temperatureThin film solar cellbusiness.industryTransparent conductiveOptical propertieSilver layerHigh transmittanceMultilayersMulti-layer-coatingZnO Electric conductivityMeasured propertiebusinessSubstrate
researchProduct

High-frequency conductive hearing loss as a diagnostic test for incomplete ossicular discontinuity in non-cholesteatomatous chronic suppurative otiti…

2017

Chronic suppurative otitis media, with or without cholesteatoma, may lead to erosion of the ossicles and discontinuity of the ossicular chain. In incomplete ossicular discontinuity (IOD), partial erosion of the ossicles occurs, but some sound transmission is noted throughout the ossicular chain. High-frequency conductive hearing loss (HfCHL) has been considered a hallmark of incomplete ossicular discontinuity. This study aims to evaluate the use of HfCHL as a preoperative predictor of IOD in patients with non-cholesteatomatous chronic suppurative otitis media. The HfCHL test was defined as the preoperative air-bone gap (ABG) at 4 kHz minus the average of the ABG at 0.25 and 0.5 kHz. The tes…

MaleMedical DoctorsHealth Care ProvidersChronic Suppurative Otitis MediaHearing Loss Conductivelcsh:MedicineOtologyDeafnessOtitis Media Suppurative0302 clinical medicineMedicine and Health SciencesMedical PersonnelProspective Studieslcsh:Science030223 otorhinolaryngologyHearing DisordersEar OssiclesMultidisciplinarymedicine.diagnostic_testCholesteatomaAudiologyMiddle AgedConductive hearing lossProfessionsmedicine.anatomical_structureMiddle earAudiometry Pure-ToneFemaleRadiologymedicine.symptomAnatomyResearch ArticleAdultmedicine.medical_specialtySoft TissuesAdolescentHearing lossSurgical and Invasive Medical ProceduresSensitivity and Specificity03 medical and health sciencesYoung AdultDiagnostic MedicinePhysiciansmedicineotorhinolaryngologic diseasesHumansSurgeonsOssiclesbusiness.industrylcsh:RMiddle EarBiology and Life SciencesGold standard (test)medicine.diseaseHealth CareOtitis MediaBiological TissueOtorhinolaryngologyEarsPeople and Placeslcsh:QPopulation Groupingssense organsAudiometrybusinessHead030217 neurology & neurosurgeryPLoS ONE
researchProduct

The role of atopy in otitis media with effusion among primary school children: audiological investigation

2010

The objective of this study was to evaluate the role of atopy in otitis media with effusion (OME) in children attending primary school in western Sicily focusing on the audiological characteristics among atopic and non-atopic subjects suffering from OME. A total of 310 children (5-6 years old) were screened by skin tests and divided into atopics (G1) and non-atopics (G2). The samples were evaluated for OME by pneumatic otoscopy, tympanogram and acoustic reflex tests. The parameters considered were: documented persistent middle ear effusion by otoscopic examination for a minimum of 3 months; presence of B or C tympanogram; absence of ipsilateral acoustic reflex and a conductive hearing loss …

MalePediatricsmedicine.medical_specialtyEustachian tubeHearing lossOME; otitis media with effusion; allergy; Auditory tube dysfunction;Hearing Loss ConductivePrevalenceOtoscopyAtopyotorhinolaryngologic diseasesHypersensitivityPrevalenceMedicineHumansotitis media with effusionOMEAcoustic reflexChildSicilySkin Testsbusiness.industryGeneral Medicinemedicine.diseaseallergyReflex AcousticConductive hearing lossSettore MED/32 - Audiologiabody regionsAuditory tube dysfunctionOtitismedicine.anatomical_structureSettore MED/31 - OtorinolaringoiatriaOtorhinolaryngologyEffusionAcoustic Impedance TestsChild PreschoolFemalemedicine.symptombusiness
researchProduct